VOP Cables

 

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

2×0.5

7.6

31.0

86

20×0.5

14.4

158.0

491

3×0.5

8.3

37.0

98

25×0.5

16.2

197.0

508

4×0.5

8.9

46.0

107

30×0.5

16.8

234.0

217

5×0.5

9.1

58.0

122

34×0.5

17.1

268.0

532

7×0.5

10.5

67.0

210

36×0.5

17.7

281.0

576

12×0.5

11.8

96.0

242

42×0.5

19.2

330.0

605

14×0.5

12.2

102.0

304

50×0.5

21.2

393.0

738

16×0.5

13.1

125.0

378

18×0.5

13.9

145.0

432

2×0.75

7.8

46.0

102

YSLYCY JZ HF 4G0.75 mm²

Application

This type is ideal for use in the machine tool industry, in robotics, in machine production and in applications where high flexibility is required. Due to the outer sheath, the high flexibility of its cores and the fleece core wrapping, this type is ideal for application where continuous movement is necessary. The screening of this type protects the signal from interferences.

Cable structure

Technical data

CoresBare copper, fine wire conductors according to DIN VDE 0295 cl.6

Core insulationSpecial PVCCores stranded in layers

Color codingBlack cores with white numbering to DIN VDE 0293All cables made of 3 cores and above contain green/yellow earthing core in the outer layer

Core wrappingFleece tape

Inner sheathPVC

ScreeningTinned copper, braiding, 80% coverageOuter sheathPVC TM2, grey color RAL 7001, self-extinguising and flame retartand according to IEC 60332-1

SpecificationsDIN VDE 0281

Temperature rangeFlexing from -5°C up to +80°CFixed installation from -40°C up to +80°C

Nominal voltageUo/U 300/500 V

Insulation resistance20 MΩ/km

Minimum bending radiusFlexing 10 x cable ØFixed installation 5 x cable Ø

YSLYCY-JZ-HF

| flexible cables, CU-screened, for applications | of continuous movement

www.vopcables.com

Control Cables

 

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

3×0.75

8.3

54.0

125

4×1.5

10.8

112.0

243

4×0.75

8.9

69.0

173

5×1.5

11.7

132.0

288

5×0.75

9.4

71.0

196

7×1.5

12.6

218.0

403

7×0.75

11.1

84.0

215

12×1.5

14.9

309.0

592

12×0.75

13.2

135.0

342

18×1.5

17.6

480.0

844

14×0.75

13.4

160.0

405

25×1.5

21.2

570.0

1097

16×0.75

14.2

178.0

449

41×1.5

26.2

855.0

1097

18×0.75

14.9

197.0

528

50Χ1.5

29.0

960.0

1210

20×0.75

15.6

210.0

545

61×1.5

31.2

1010.0

1690

25×0.75

18.2

310.0

572

30×0.75

18.7

406.0

638

3×2.5

11.1

138.0

213

42×0.75

21.3

572.0

786

4×2.5

11.5

166.0

254

50×0.75

23.3

690.0

925

5×2.5

13.2

120.0

339

7×2.5

15.1

230.0

405

2×1

8.3

48.0

104

12×2.5

18.4

359.0

702

3×1

8.8

59.0

125

4×1

9.5

71.0

158

3×4

13.2

218.0

289

5×1

10.1

94.0

197

4×4

14.6

220.0

370

7×1

11.7

108.0

271

5×4

15.8

310.0

436

12×1

14.0

193.0

418

18×1

17.0

296.0

604

4×6

16.2

292.0

520

25×1

19.8

402.0

798

5×6

18.7

435.0

621

34×1

21.8

505.0

1022

41×1

22.6

607.0

1248

4×10

21.4

472.0

810

50×1

24.7

729.0

1382

5×10

23.3

582.0

984

65×1

33.1

896.0

1740

4×16

23.6

831.0

1196

2×1.5

9.4

75.0

170

5×16

26.7

1032.0

1516

3×1.5

9.9

90.0

203

YSLYCY-JZ-HF flexible cables, CU-screened, for applications of continuous movement

For cross sections, that are not mentioned on the adove board, please contact our company.

www.vopcables.com

Control Cables

Contact