Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
2x2x0.14
5.10
6.20
27.30
2x2x0.25
5.60
9.80
39.00
3x2x0.14
5.90
8.50
33.00
3x2x0.25
5.80
14.90
48.00
4x2x0.14
6.40
11.30
41.10
4x2x0.25
6.50
20.10
60.00
5x2x0.14
7.00
14.00
46.20
6x2x0.25
7.90
31.00
83.00
6x2x0.14
7.50
17.10
53.00
8x2x0.25
8.80
42.00
101.00
7x2x0.14
7.90
19.40
57.60
10.x2x0.25
9.80
51.00
115.00
8x2x0.14
8.20
22.50
65.00
12x2x0.25
10.70
62.00
140.00
10x2x0.14
8.80
27.10
81.00
14x2x0.25
11.40
69.00
162.00
12x2x0.14
9.60
35.10
97.00
16x2x0.25
12.50
82.00
191.00
14x2x0.14
10.00
37.6
107.00
18x2x0.25
12.90
93.00
218.00
16x2x0.14
10.60
45.00
119.00
20x2x0.25
13.50
103.00
246.00
18x2x0.14
11.30
48.40
125.50
24x2x0.25
14.60
121.00
284.00
20x2x0.14
11.90
54.00
137.00
25x2x0.25
15.50
127.00
305.00
22x2x0.14
12.70
61.20
149.00
28x2x0.25
15.80
139.00
348.00
LiYY-TP
LiYY (TP) 2x2x0.25 mm²
Application
LiYY TP is data transmission cable, for measuring and control systems. Ideal when flexibility and free movement are required. Suitable for applications where minimum outer diameter is necessary. The fact that the cores of this type are twisted in pairs offers protection from interference in the signal transmission.
Cable structure
Technical data
CoresBare copper, fine wire conductors according to DIN VDE 0295 cl.5 and IEC 60228 cl.5
Core insulationSpecial PVC YI2
Core coding Colored cores according to DIN 47100, without color repetitionCores stranded in pairs
Outer sheathSpecial PVC YM2, grey color RAL 7032Flame Retardant according to IEC 60332-1
SpecificationsDIN VDE 0812, 0814
Temperature rangeFlexing from -5ºC up to +70ºCFixed installation from -30ºC up to +80ºC
Nominal voltage 250V
Insulation resistance 20 MΩ x km
Capacitance0,14mm2 90 pF/m 0.25mm² 150 pF/m
Impedance78 Ω
Inductance0,65 mH/km
Minimum bending radius10 x Ø cable minimum
| flexible data cable
www.vopcables.com
Data Cables