A-2Y(L)2Y
Application
This cable is used in fixed outdoor telecommunication connections, extensions, in security and fire warning systems. They can also be used for underground laying. Their use in power and supply installations is not recommended.
Cable structure
Technical data
CoresSolid of bare copper, diameter 0.6mm and 0.8mm
Core insulationPE (2Y) according to DIN VDE 0816
Color codingCores are marked with black rings according to DIN VDE 0816Cores are twisted to quads, each 5 quads stranded to sub units, each 5 or 10 sub units are twisted together
Core wrappingPlastic tape
ScreeningPE-coated aluminium foil
Outer sheathPE in black color
SpecificationsDIN VDE 0816
Temperature rangeFlexing from -20ºC up to +50ºCFixed installation from -30ºC up to +70ºC
Nominal voltage(maximum) 300 V
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
2x2x0.6
8.0
11.0
80
2x2x0.8
10.0
20.0
102
4x2x0.6
10.0
23.0
98
4x2x0.8
10.9
40.0
118
6x2x0.6
11.4
34.0
107
6x2x0.8
11.4
60.0
148
10x2x0.6
13.3
57.0
145
10x2x0.8
13.3
101.0
207
20x2x0.6
16.6
113.0
229
20x2x0.8
16.6
201.0
346
30x2x0.6
19.5
170.0
314
30x2x0.8
19.5
302.0
482
40x2x0.6
21.7
226.0
393
40x2x0.8
21.7
402.0
614
50x2x0.6
23.4
283.0
470
50x2x0.8
23.4
503.0
739
70x2x0.6
27.3
396.0
621
70x2x0.8
27.3
704.0
1012
100x2x0.6
31.4
565.0
875
100x2x0.8
31.4
1005.0
1402
150x2x0.6
37.5
848.0
1223
150x2x0.8
37.5
1508.0
2030
200x2x0.6
42.2
1131.0
1590
200x2x0.8
42.2
2011.0
2628
250x2x0.6
48.1
1414.0
1963
250x2x0.8
48.1
2514.0
3304
300x2x0.6
52.1
1696.0
2321
300x2x0.8
52.1
3016.0
3905
350x2x0.6
53.5
1979.0
2809
350x2x0.8
56.5
3519.0
4940
400x2x0.6
59.9
2262.0
3090
400x2x0.8
59.9
4022.0
5181
500x2x0.8
66.0
5027.0
6367
600x2x0.8
72.8
6032.0
8200

| screened telephone cables for outdoor use | without petrol-jelly filler
www.vopcables.com