VOP Cables

Vop_Catalogue_2020_WEB_USE_ONLY_ENG-89

A-2Y(L)2Y

Application

This cable is used in fixed outdoor telecommunication connections, extensions, in security and fire warning systems. They can also be used for underground laying. Their use in power and supply installations is not recommended.

Cable structure

Technical data

CoresSolid of bare copper, diameter 0.6mm and 0.8mm

Core insulationPE (2Y) according to DIN VDE 0816

Color codingCores are marked with black rings according to DIN VDE 0816Cores are twisted to quads, each 5 quads stranded to sub units, each 5 or 10 sub units are twisted together

Core wrappingPlastic tape

ScreeningPE-coated aluminium foil

Outer sheathPE in black color

SpecificationsDIN VDE 0816

Temperature rangeFlexing from -20ºC up to +50ºCFixed installation from -30ºC up to +70ºC

Nominal voltage(maximum) 300 V

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

Diameter

Ø mm

Copper

Weight

kg/km

Cable

Weight

kg/km

No. cores x

cross-sec

mm²

Outer

Diameter

Ø mm

Copper

Weight

kg/km

Cable

Weight

kg/km

2x2x0.6

8.0

11.0

80

2x2x0.8

10.0

20.0

102

4x2x0.6

10.0

23.0

98

4x2x0.8

10.9

40.0

118

6x2x0.6

11.4

34.0

107

6x2x0.8

11.4

60.0

148

10x2x0.6

13.3

57.0

145

10x2x0.8

13.3

101.0

207

20x2x0.6

16.6

113.0

229

20x2x0.8

16.6

201.0

346

30x2x0.6

19.5

170.0

314

30x2x0.8

19.5

302.0

482

40x2x0.6

21.7

226.0

393

40x2x0.8

21.7

402.0

614

50x2x0.6

23.4

283.0

470

50x2x0.8

23.4

503.0

739

70x2x0.6

27.3

396.0

621

70x2x0.8

27.3

704.0

1012

100x2x0.6

31.4

565.0

875

100x2x0.8

31.4

1005.0

1402

150x2x0.6

37.5

848.0

1223

150x2x0.8

37.5

1508.0

2030

200x2x0.6

42.2

1131.0

1590

200x2x0.8

42.2

2011.0

2628

250x2x0.6

48.1

1414.0

1963

250x2x0.8

48.1

2514.0

3304

300x2x0.6

52.1

1696.0

2321

300x2x0.8

52.1

3016.0

3905

350x2x0.6

53.5

1979.0

2809

350x2x0.8

56.5

3519.0

4940

400x2x0.6

59.9

2262.0

3090

400x2x0.8

59.9

4022.0

5181

500x2x0.8

66.0

5027.0

6367

600x2x0.8

72.8

6032.0

8200

| screened telephone cables for outdoor use | without petrol-jelly filler

www.vopcables.com

Telephone Cables