VOP Cables

Vop_Catalogue_2020_WEB_USE_ONLY_ENG-116

Application

This cable type is used in heating house devices, software systems, nautical lighting equipment and whenever there is high temperatures and rapid temperature changes. It is halogen free and resistant to oils petrol and fats.

F6Y06Y

Cable structure

Technical data

CoresStranded, tinned copper wires according to DIN VDE 0295 cl.5

Core insulationFEP

Outer sheathFEP

SpecificationDIN VDE 0207 part 6

Temperature rangeFrom -100ºC up to +205ºC

Nominal voltage900 V

| multicore FEP cables

Cross Sec.

AWG

Approximately

Outer Diameter

Ø mm

Copper Weight kg/km

Cable Weight

kg/km

Max. resistance

Ω/km to 20ºC

2xAWG 22

3.1

6.5

17.0

53.6

3xAWG 22

3.2

9.8

21

6xAWG 22

4.4

19.6

35.6

7xAWG 22

4.4

22.8

41.5

2xAWG 20

3.4

9.6

22.5

33.7

3xAWG 20

3.6

14.4

30.3

6xAWG 20

5.1

28.8

52

7xAWG 20

5.1

33.6

59

2xAWG 18

4.1

14.4

31

21.1

3xAWG 18

4.3

21.6

41

6xAWG 18

6.7

42.87

73

7xAWG 18

6.7

50

83

Cores x cross-sec in mm²

Approximately

Outer Diameter

Ø mm

Copper Weight kg/km

Cable Weight

kg/km

1×0.50

1.50

5.60

6.90

1×0.75

1.80

9.10

9.30

1×1.00

1.90

11.90

12.00

1×1.50

2.30

15.30

16.90

1×2.50

2.70

25.20

29.20