Application
This cable type is used in metal industries, in lighting equipment and in electric devices with HAR requirements, in high temperature areas and wherever there is a rapid temperature change. It is halogen free and resistant to oils, petrol and fats from vegetables and animals.
H05SS-F
Cable structure
Technical data
CoresTinned copper fine wires stranded according toDIN VDE 0295 cl. 5
Color codingColored cores according to DIN VDE 0293
Core insulationSilicone
Outer sheathSilicone in black or redbrown color
SpecificationsDIN VDE 0250
Temperature rangeFrom -60ºC up to +180ºC
Nominal voltageUo/U 300/500 V
| multicore silicone cables ◀HAR▶
Cores x cross-sec in mm²
Approximately
Outer Diameter
Ø mm
Copper Weight kg/km
Cable Weight
kg/km
2×0.75
6.4
13.3
53
3×0.75
7
20.5
70
4×0.75
7.6
28.9
84
5×0.75
8.5
35.9
103
2×1
8
18.9
65
3×1
7.2
27.6
75
4×1
7.8
37.8
94
5×1
8.8
47.9
117
2×1.5
8.2
27.6
95
3×1.5
8.7
41.5
115
4×1.5
9.7
57
143
5×1.5
10.6
71
170
2×2.5
9.8
46.3
142
3×2.5
10.4
69.8
172
4×2.5
11.5
94.4
213
5×2.5
12.9
118.9
262
3×4
12.1
113.5
245
4×4
13.4
190.6
306
3×6
13.8
169.4
335
4×6
15.2
228.7
417
www.vopcables.com