Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
3G0.5
6.2
14.4
60
65G0.5
25.7
312.0
823
4G0.5
6.8
19.2
65
5G0.5
7.4
24.0
86
3G0.75
6.7
21.6
65
7G0.5
9.4
33.6
118
4G0.75
7.3
28.8
79
12G0.5
11.5
58.0
165
5G0.75
8.3
36.0
105
18G0.5
13.6
86.0
184
7G0.75
9.7
50.4
145
25G0.5
16.5
120.0
258
10G0.75
11.9
68.0
196
27G0.5
16.9
130.0
360
12G0.75
12.5
86.0
242
34G0.5
19.0
163.0
370
18G0.75
14.4
130.0
315
36G0.5
19.3
172.0
486
25G0.75
17.9
180.0
450
41G0.5
21.3
196.0
575
27G0.75
18.2
194.0
495
50G0.5
22.2
240.0
660
34G0.75
20.3
245.0
615
61G0.5
23.8
293.0
785
36G0.75
20.6
259.0
640
<VDE> <HAR> H05VV5-F 4G2.5 mm²
Application
This type is used as measuring and control cable in tool machineries, air-conditioners, conveyor belts and into machines as connecting cables. There have been manufactured ans tested according to DIN VDE 0250 part 405 and HD 21.13 S1. H05VV-F cable is totally oil and chemical resistant, self-extinguishing and flame retardant to IEC 60332.1. Recommended for medium mechanical stresses in indoor environment.
Cable structure
Technical data
CoresΒare copper, fine stranded wire conductors toDIN VDE 0295 cl.5 and IEC 60228 cl.5
Core insulationPVC TI2, according to DIN VDE 281 part 1Cores stranded in layers
Color codingBlack with white numbering according to DIN VDE 0293All cables made of 3 cores and above contain green/yellow earthing core in the outer layer
Outer sheathPVC TM2, grey color RAL 7001 self-extinguishing and flame retardant according to DIN VDE 0472 part 804 and IEC 60332-1
SpecificationsControl cables made of special PVC, according to DIN VDE 0250 part 405 HD 21.13S1
Temperature rangeFlexing from -5°C up to +70°CFixed installation from -40°C up to +70°C
Nominal voltageUo/U 300/500 V
Insulation resistance20 MΩ/km minimum
Minimum bending radius7.5 x cable Ø minimum
H05VV5-F
| flexible, control cable with VDE approval (NYSLYÖ-JZ)
www.vopcables.com
Control Cables
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
41G0.75
21.3
296.0
715
7G1.5
11.7
101.0
225
50G0.75
23.6
360.0
890
10G1.5
13.5
140.0
298
61G0.75
26.0
439.0
1020
12G1.5
14.2
173.0
330
65G0.75
27.5
468.0
1079
16G1.5
16.0
230.0
439
18G1.5
17.1
259.0
500
3G1
7.0
29.0
75
25G1.5
21.0
360.0
695
4G1
7.8
38.4
100
27G1.5
21.7
389.0
720
5G1
8.9
48.0
121
32G1.5
22.4
461.0
860
7G1
10.4
67.0
180
34G1.5
23.9
490.0
915
10G1
12.8
96.0
245
36G1.5
24.3
518.0
940
12G1
13.1
115.0
268
41G1.5
26.1
590.0
1085
16G1
15.2
154.0
365
50G1.5
27.8
720.0
1370
18G1
15.9
173.0
400
61G1.5
29.9
878.0
1635
25G1
19.2
240.0
546
27G1
19.6
260.0
585
3G2.5
9.7
72.0
150
34G1
21.9
326.0
725
4G2.5
10.9
96.0
205
36G1
22.0
346.0
770
5G2.5
11.9
120.0
240
41G1
22.5
394.0
830
7G2.5
14.3
168.0
345
50G1
25.9
480.0
1045
12G2.5
17.9
288.0
540
61G1
28.1
586.0
1254
18G2.5
21.5
432.0
800
65G1
28.6
624.0
1325
25G2.5
26.0
600.0
1150
34G2.5
29.1
816.0
1520
3G1.5
7.8
43.0
95
50G2.5
34.8
1200.0
2185
4G1.5
8.7
58.0
126
61G2.5
37.0
1464.0
2630
5G1.5
9.6
72.0
152
H05VV5-F | flexible, control cable with VDE approval (NYSLYÖ-JZ)