VOP Cables

 

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

3G0.5

6.2

14.4

60

65G0.5

25.7

312.0

823

4G0.5

6.8

19.2

65

5G0.5

7.4

24.0

86

3G0.75

6.7

21.6

65

7G0.5

9.4

33.6

118

4G0.75

7.3

28.8

79

12G0.5

11.5

58.0

165

5G0.75

8.3

36.0

105

18G0.5

13.6

86.0

184

7G0.75

9.7

50.4

145

25G0.5

16.5

120.0

258

10G0.75

11.9

68.0

196

27G0.5

16.9

130.0

360

12G0.75

12.5

86.0

242

34G0.5

19.0

163.0

370

18G0.75

14.4

130.0

315

36G0.5

19.3

172.0

486

25G0.75

17.9

180.0

450

41G0.5

21.3

196.0

575

27G0.75

18.2

194.0

495

50G0.5

22.2

240.0

660

34G0.75

20.3

245.0

615

61G0.5

23.8

293.0

785

36G0.75

20.6

259.0

640

<VDE> <HAR> H05VV5-F 4G2.5 mm²

Application

This type is used as measuring and control cable in tool machineries, air-conditioners, conveyor belts and into machines as connecting cables. There have been manufactured ans tested according to DIN VDE 0250 part 405 and HD 21.13 S1. H05VV-F cable is totally oil and chemical resistant, self-extinguishing and flame retardant to IEC 60332.1. Recommended for medium mechanical stresses in indoor environment.

Cable structure

Technical data

CoresΒare copper, fine stranded wire conductors toDIN VDE 0295 cl.5 and IEC 60228 cl.5

Core insulationPVC TI2, according to DIN VDE 281 part 1Cores stranded in layers

Color codingBlack with white numbering according to DIN VDE 0293All cables made of 3 cores and above contain green/yellow earthing core in the outer layer

Outer sheathPVC TM2, grey color RAL 7001 self-extinguishing and flame retardant according to DIN VDE 0472 part 804 and IEC 60332-1

SpecificationsControl cables made of special PVC, according to DIN VDE 0250 part 405 HD 21.13S1

Temperature rangeFlexing from -5°C up to +70°CFixed installation from -40°C up to +70°C

Nominal voltageUo/U 300/500 V

Insulation resistance20 MΩ/km minimum

Minimum bending radius7.5 x cable Ø minimum

H05VV5-F

| flexible, control cable with VDE approval (NYSLYÖ-JZ)

www.vopcables.com

Control Cables

 

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

41G0.75

21.3

296.0

715

7G1.5

11.7

101.0

225

50G0.75

23.6

360.0

890

10G1.5

13.5

140.0

298

61G0.75

26.0

439.0

1020

12G1.5

14.2

173.0

330

65G0.75

27.5

468.0

1079

16G1.5

16.0

230.0

439

18G1.5

17.1

259.0

500

3G1

7.0

29.0

75

25G1.5

21.0

360.0

695

4G1

7.8

38.4

100

27G1.5

21.7

389.0

720

5G1

8.9

48.0

121

32G1.5

22.4

461.0

860

7G1

10.4

67.0

180

34G1.5

23.9

490.0

915

10G1

12.8

96.0

245

36G1.5

24.3

518.0

940

12G1

13.1

115.0

268

41G1.5

26.1

590.0

1085

16G1

15.2

154.0

365

50G1.5

27.8

720.0

1370

18G1

15.9

173.0

400

61G1.5

29.9

878.0

1635

25G1

19.2

240.0

546

27G1

19.6

260.0

585

3G2.5

9.7

72.0

150

34G1

21.9

326.0

725

4G2.5

10.9

96.0

205

36G1

22.0

346.0

770

5G2.5

11.9

120.0

240

41G1

22.5

394.0

830

7G2.5

14.3

168.0

345

50G1

25.9

480.0

1045

12G2.5

17.9

288.0

540

61G1

28.1

586.0

1254

18G2.5

21.5

432.0

800

65G1

28.6

624.0

1325

25G2.5

26.0

600.0

1150

34G2.5

29.1

816.0

1520

3G1.5

7.8

43.0

95

50G2.5

34.8

1200.0

2185

4G1.5

8.7

58.0

126

61G2.5

37.0

1464.0

2630

5G1.5

9.6

72.0

152

H05VV5-F | flexible, control cable with VDE approval (NYSLYÖ-JZ)

For cross sections, that are not mentioned on the adove board, please contact our company.

For Racks and relative accessories, please ask us for the special VOP Racks catalogue.

www.vopcables.com

Control Cables

Contact

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.