Application
MGCH is a marine power cable used on fixed installations. Suitable to be installed in any place, even on a ship deck.
Cable structure
Technical data
CoresFlexible bare copper conductors to DINVDE 0295 cl.2 and IEC 60228 cl.2
Core coding
1 core: black2 cores: black, white3 cores: black, white, brown4 cores: black, white, brown, blue5 cores: black, white, brown, blue, green/yellow> 5 cores: white with black numbers
Core insulationXLPE to IEC 60092-351
ScreeningΒraided copper, coverage 90% according to IEC 60092-350
Outer sheathPolyolefine, color grey according to IEC 60092-359
SpecificationsIEC 60092-353
Nominal voltageUo/U 0.6/1 kV
Temperature rangeUp to +85ºCFlame retardant to IEC 60332-1 & IEC 60332-3AHalogen free to IEC 60754Minimum temperature during installation -15ºC
ApprovalsABS, BV, DNV, GL, LRS, Class NK, RINA, RMRS
| marine power cable 0.6/1 kV halogen free
MGCH
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
Kg/km
Cable
Weight
Kg/km
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
Kg/km
Cable
Weight
Kg/km
1×6
7
58
90
3×1.5
9.5
43
100
1×10
8
96
135
3×2.5
10.5
72
140
1×16
9.5
154
200
3×4
12
115
195
1×25
11
240
310
3×6
13.5
173
265
1×35
13
336
430
3×10
15.5
288
410
1×50
15
480
560
3×16
18
461
640
1×70
16.5
672
800
3×25
22
720
950
1×95
18.5
912
1060
1×120
21
1152
1325
4×1.5
10.5
58
130
1×150
23
1440
1615
4×2.5
12
96
180
1×185
26
1776
2015
4×4
13
154
250
1×240
29.5
2304
2660
4×6
15
230
335
4×10
17
384
515
2×1.5
9
29
80
2×2.5
10
48
110
5×1.5
11.5
72
165
2×4
11
77
145
7×1.5
12.5
101
200
2×6
12.5
115
215
12×1.5
16.5
173
330
For cross sections that are not mentioned on the table above, please contact our sales department.
www.vopcables.com
Marine Cables