VOP Cables

Application

N2XS2Y is used on fixed installations mostly for outdoor power supply stations. Suitable for use on cable trays, switch-boards and power stations. It also can be laid easily in difficult line guides.The inner conducting layer between the conductor and the XLPE and the firmly bonded outer conducting layer on the XLPE, assures a construction free of partial discharges with high operational reliability.

Cable structure

Technical data

CoresCopper conductor of stranded wires according to DIN VDE 0295 cl.2 and IEC60228 cl.2

Core insulation1st insulationInner semi-conducting coating

2nd insulationCross-linked compound PE (XLPE) DIX8according to HD 620 S2

3rd insulationOuter semi-conducting coating spliced with the XLPE insulation

Wrapping Conductive material

ScreeningCopper wire braiding with one or two tapes applied helically

Outer sheathPE type HD 620 S2 in black color

StandardsDIN VDE 0276, HD 620 S2 and IEC 60502

Temperature rangeDuring the installation up to -20ºCFixed installation up to +90ºCShort circuit temperature up to +250ºC (up 5 sec)

Nominal voltageUo/U 6/10 kV max 12 kVUo/U 12/20 kV max 24 kVUo/U 18/30 kV max 36 kV

Minimum bending radius 15 x cable Ø

| single core medium voltage cable 6/10 kV, | 12/20 kV, 18/30 kV with outer sheath of polyethylene

N2XS2Y

Cores x cross-secin mm²

Nominalvoltage

Approximately

Outer Diameter

Ø mmMin Max

Copper Weight

kg/km

Cable Weight

kg/km

1x35rm/16

6/10

23.0-28.0

518.0

910

1x50rm/16

6/10

24.0-29.0

662.0

990

1x70rm/16

6/10

26.0-31.0

854.0

1205

1x95rm/16

6/10

26.0-32.0

1098.0

1760

1x120rm/16

6/10

28.0-34.0

1340.0

1860

1x150rm/16

6/10

29.0-35.0

1622.0

2020

www.vopcables.com

Medium Voltage Cables

N2XS2Y | single core medium voltage cable 6/10 kV, 12/20 kV, 18/30 kV with outer sheathof polyethylene

Cores x cross-secin mm²

Nominalvoltage

Approximately

Outer Diameter

Ø mmMin Max

Copper Weight

kg/km

Cable Weight

kg/km

1x185rm/25

6/10

31.0-37.0

2059.0

2470

1x240rm/16

6/10

33.0-39.0

2486.0

2960

1x240rm/25

6/10

33.0-39.0

2587.0

3020

1x300rm/25

6/10

36.0-41.0

3163.0

3630

1x400rm/35

6/10

40.0-45.0

4234.0

4560

1x500rm/35

6/10

43.0-48.0

5194.0

5580

1x35rm/16

12/20

27.0-32.0

518.0

960

1x50rm/16

12/20

28.0-33.0

662.0

1160

1x70rm/16

12/20

30.0-35.0

854.0

1410

1x95rm/16

12/20

31.0-36.0

1094.0

1670

1x120rm/16

12/20

33.0-38.0

1334.0

1960

1x150rm/16

12/20

34.0-39.0

1622.0

2220

1x150rm/25

12/20

34.0-39.0

1723.0

2310

1x185rm/16

12/20

36.0-41.0

1958.0

2620

1x185rm/25

12/20

36.0-41.0

2059.0

2670

1x240rm/16

12/20

39.0-44.0

2486.0

3160

1x240rm/25

12/20

39.0-44.0

2587.0

3270

1x300rm/25

12/20

41.0-46.0

3163.0

3880

1x400rm/35

12/20

44.0-49.0

4234.0

4820

1x500rm/35

12/20

47.0-52.0

5194.0

5860

1x50rm/16

18/30

32.0-38.0

662.0

1410

1x70rm/16

18/30

34.0-40.0

854.0

1660

1x95rm/16

18/30

35.0-41.0

1094.0

1970

1x120rm/16

18/30

37.0-43.0

1334.0

2220

1x150rm/25

18/30

38.0-44.0

1723.0

2650

1x185rm/25

18/30

40.0-46.0

1958.0

2980

1x240rm/25

18/30

42.0-48.0

2587.0

3570

1x300rm/25

18/30

45.0-51.0

3163.0

4220

1x400rm/35

18/30

48.0-54.0

4234.0

5170

1x500rm/35

18/30

51.0-57.0

5194.0

6260

This cable is also available in types N2XS(F)2Y and N2XS(FL)2Y in 6/10 kV, 12/20 kV, 18/30 kV.