Application
This type is used on indoor installations, wherever high security specifications are required for the protection from fire of human life. When burnt this cable, the circuit integrity is maintained for 90 minutes, while there appear low smoke and halogen emissions. Not recommended for direct burial underground or underwater without conduits or tubes.

Cable structure
Technical data
CoresSolid or stranded bare copper wires according toDIN VDE 0295 cl.1 and IEC 60228 cl.1 and cl.2
Core insulation1st insulationΗigh quality, flame resistant, ceramic compound2nd insulationCross-linked polymer compound HxI1 according toDIN VDE 0266
Color codingAccording to DIN VDE 0293, from 3 cores and abovecontains green/yellow earthing core
WrappingHalogen free compound
ScreeningConcetric conductor of copper wires,wrapped with copper tape
SeperatorPlastic tape
Outer sheathPolyolefin compound HM4 according to DIN VDE 0276-604, CENELEC HD 604 S1, in orange color
re = round conductor, single wire
rm = round conductor, multiple-wire
SpecificationDIN VDE 0276-604
Temperature rangeDuring installation: from -5°C up to +50°C
Fixed installation: from -5°C up to +90°C
Nominal voltageUo/U 0.6/1 kV
Minimum bending radius12 x cable Ø
Halogen freeDIN VDE 0482-267, EN 50267 and IEC 60754-2
Flame retardantDIN VDE 0482-265, EN 50265 and IEC 60332-1
Reduced flame propagationsDIN VDE 0472-804/C, CENELEC HD 405.3and IEC 60332-3 cat C and cat A
Low smoke emissionDIN VDE 0482-268, EN 50268 and IEC 61034-1
Insulation integrity FE180DIN VDE 0472-814, IEC 60331
Funcionality E90DIN 41012-12
NHXCHFE180/E90
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
3×1.5 re/1.5
15.0
66.0
300
3×25 rm/16
28.0
1003.0
1624
3×2.5 re/2.5
16.0
104.0
381
3×35 rm/16
31.0
1402.0
2001
3×4 re/4
18.0
161.0
482
3×50 rm/25
35.0
1723.0
2684
3×6 re /6
19.0
240.0
589
3×70 rm/35
39.0
2410.0
3620
3×10 re/10
21.0
408.0
802
3×95 rm/50
45.0
3296.0
4791
3×16 rm/16
25.0
643.0
1195
3×120 rm/70
47.0
4236.0
5818
NHXCH FE 180/E90 0.6/1KV
| fire resistant power and control cables 0.6/1 kV, | with concentric conductor for circuit integrity 90 minutes
Fire Resistant Cables
www.vopcables.com

NHXCH FE180/E90 fire resistant power and control cables 0.6/1 kV, with concentric conductor for circuit integrity 90 minutes
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
No. cores x
cross-sec
mm²
Outer
Diameter
Ø mm
Copper
Weight
kg/km
Cable
Weight
kg/km
3×150 rm/70
52.0
5100.0
7025
4×150 rm/70
57.0
6540.0
8771
3×185 rm/95
58.0
6383.0
8705
4×185 rm/95
64.0
8159.0
10859
3×240 rm/120
65.0
8242.0
11271
4×240 rm/120
71.0
10546.0
14071
4×1.5 re /1.5
16.0
81.0
367
7×1.5 re/2.5
19.0
133.0
516
4×2.5 re/2.5
17.0
128.0
447
7×2.5 re/2.5
20.0
200.0
626
4×4 re /4
19.0
200.0
569
4×6 re/6
20.0
297.0
699
12×1.5 re/2.5
24.0
205.0
797
4×10 re/10
23.0
504.0
981
12×2.5 re/4
26.0
334.0
1007
4×16 rm/16
27.0
796.0
1433
4×25 rm/16
31.0
1142.0
1970
24×1.5 re/6
33.0
413.0
1459
4×35 rm/16
34.0
1526.0
2493
24×1.5re/10
36.0
696.0
1870
4×50 rm/25
38.0
2203.0
3315
4×70 rm/35
43.0
3082.0
4479
30×1.5 re/6
35.0
499.0
1689
4×95 rm/50
49.0
4208.0
5934
30×2.5 re/10
38.0
840.0
2175
4×120 rm/70
52.0
5388.0
7205
For cross sections that are not mentioned on the above table, please contact our sales department.
www.vopcables.com
Fire Resistant Cables