VOP Cables

 

VOP CABLES YSL CY 4×1 mm²

Application

YSLCY is a data cable also used in control and measurement installations, computers and industrial machinery. The copper screening offers signal protection from electromagnetic interferences.

Cable structure

Technical data

CoresΒare copper, fine wire conductors to DIN VDE 0295 cl.5

Core InsulationPVC TI2

Core codingBlack cores with continuous numbering in white, according to DIN VDE 0293All cables with 3 cores and above contain a green/yellow earthing core

ScreeningTinned copper braided, 83% coverage

Outer sheathPVC TM2 grey color RAL 7001Flame Retardant according to IEC 60332-1

SpecificationsDIN VDE 0245, 0281

Temperature rangeFlexing from -5ºC up to +80ºCFixed installation from -30ºC up to +80ºC

Nominal voltage Uo/U300/500 V

Insulation resistance20 MΩ/km minimum

Minimum bending radius10 x Ø cable

Outer sheath printing: VOP CABLES YSLCY (No.cores) x (cross sec.) mm² CE

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

2×0.75

6.20

38.30

59.50

30×0.75

15.80

315.60

452.00

3×0.75

6.60

50.20

66.40

4×0.75

7.10

57.30

77.70

2×1.00

6.60

46.20

66.00

5×0.75

7.60

70.40

93.80

3×1.00

6.90

56.10

80.90

6×0.75

8.10

87.10

113.50

4×1.00

7.50

69.40

98.90

7×0.75

8.80

96.50

131.00

5×1.00

8.00

89.10

128.00

8×0.75

9.60

110.40

146.00

6×1.00

8.70

105.30

144.80

10×0.75

10.40

140.20

180.60

7×1.00

9.30

111.50

160.00

12×0.75

10.60

151.60

203.00

8×1.00

10.10

130.60

199.00

14×0.75

11.30

167.40

225.70

10×1.00

11.00

140.10

232.60

16×0.75

11.80

183.20

276.00

12×1.00

11.40

168.30

261.00

18×0.75

12.60

207.40

293.00

16×1.00

12.50

218.50

347.00

20×0.75

13.10

238.30

321.00

24×0.75

14.70

270.10

436.00

YSLCY

| flexible data transmission cable| CU screened

www.vopcables.com

Data Cables

 

YSLCY | εύκαμπτα καλώδια μεταφοράς δεδομένων, με αριθμημένους αγωγούς και θωράκιση χαλκού

YSLCY | flexible data transmission cable CU screened

There is an extra catalogue for cable accessories.

Approximately

Approximately

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

No. cores x

cross-sec

mm²

Outer

diameter

Ø mm

Copperweightkg/km

Cableweight

kg/km

18×1.00

13.40

245.30

381.00

2×4

10.00

135.00

187.00

20×1.00

14.00

267.10

442.00

3×4

10.80

177.00

241.00

24×1.00

15.70

320.30

494.00

4×4

11.70

241.00

312.00

28×1.00

16.90

370.40

596.00

5×4

13.00

327.00

386.00

34×1.00

18.10

440.20

742.00

2×6

11.80

176.00

269.00

2×1.5

6.90

63.00

90.00

3×6

12.50

241.00

332.00

3×1.5

7.50

77.00

101.00

4×6

13.90

334.00

413.00

4×1.5

8.20

99.00

125.00

5×6

15.80

441.00

508.00

7×1.5

10.70

151.00

210.00

12×1.5

13.00

220.00

336.00

2×10

15.00

265.00

427.00

16×1.5

14.20

282.00

425.00

3×10

16.10

371.00

502.00

18×1.5

15.40

367.00

480.00

4×10

18.10

186.00

785.00

25×1.5

18.70

495.00

701.00

5×10

19.90

714.00

857.00

2×2.5

8.20

94.00

128.00

4×16

21.10

810.00

885.00

3×2.5

9.10

145.00

166.00

5×16

23.20

1040.00

1286.00

4×2.5

10.00

173.00

196.00

5×2.5

11.20

198.00

221.00

4×25

26.90

1162.00

1567.00

7×2.5

13.10

235.00

345.00

5×25

30.00

1438.00

1962.00

12×2.5

16.20

440.00

571.00

4×35

30.80

1587.00

2060.00

18×2.5

19.00

568.00

678.00

5×35

34.20

1928.00

2685.00

4×50

34.90

2150.00

3005.00

www.vopcables.com

Data Cables

Contact

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.