VOP CABLES YSL CY 4×1 mm²
Application
YSLCY is a data cable also used in control and measurement installations, computers and industrial machinery. The copper screening offers signal protection from electromagnetic interferences.
Cable structure
Technical data
CoresΒare copper, fine wire conductors to DIN VDE 0295 cl.5
Core InsulationPVC TI2
Core codingBlack cores with continuous numbering in white, according to DIN VDE 0293All cables with 3 cores and above contain a green/yellow earthing core
ScreeningTinned copper braided, 83% coverage
Outer sheathPVC TM2 grey color RAL 7001Flame Retardant according to IEC 60332-1
SpecificationsDIN VDE 0245, 0281
Temperature rangeFlexing from -5ºC up to +80ºCFixed installation from -30ºC up to +80ºC
Nominal voltage Uo/U300/500 V
Insulation resistance20 MΩ/km minimum
Minimum bending radius10 x Ø cable
Outer sheath printing: VOP CABLES YSLCY (No.cores) x (cross – sec.) mm² CE
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
2×0.75
6.20
38.30
59.50
30×0.75
15.80
315.60
452.00
3×0.75
6.60
50.20
66.40
4×0.75
7.10
57.30
77.70
2×1.00
6.60
46.20
66.00
5×0.75
7.60
70.40
93.80
3×1.00
6.90
56.10
80.90
6×0.75
8.10
87.10
113.50
4×1.00
7.50
69.40
98.90
7×0.75
8.80
96.50
131.00
5×1.00
8.00
89.10
128.00
8×0.75
9.60
110.40
146.00
6×1.00
8.70
105.30
144.80
10×0.75
10.40
140.20
180.60
7×1.00
9.30
111.50
160.00
12×0.75
10.60
151.60
203.00
8×1.00
10.10
130.60
199.00
14×0.75
11.30
167.40
225.70
10×1.00
11.00
140.10
232.60
16×0.75
11.80
183.20
276.00
12×1.00
11.40
168.30
261.00
18×0.75
12.60
207.40
293.00
16×1.00
12.50
218.50
347.00
20×0.75
13.10
238.30
321.00
24×0.75
14.70
270.10
436.00
YSLCY
| flexible data transmission cable| CU – screened
www.vopcables.com
Data Cables
YSLCY | εύκαμπτα καλώδια μεταφοράς δεδομένων, με αριθμημένους αγωγούς και θωράκιση χαλκού
YSLCY | flexible data transmission cable CU – screened
There is an extra catalogue for cable accessories.
Approximately
Approximately
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
No. cores x
cross-sec
mm²
Outer
diameter
Ø mm
Copperweightkg/km
Cableweight
kg/km
18×1.00
13.40
245.30
381.00
2×4
10.00
135.00
187.00
20×1.00
14.00
267.10
442.00
3×4
10.80
177.00
241.00
24×1.00
15.70
320.30
494.00
4×4
11.70
241.00
312.00
28×1.00
16.90
370.40
596.00
5×4
13.00
327.00
386.00
34×1.00
18.10
440.20
742.00
2×6
11.80
176.00
269.00
2×1.5
6.90
63.00
90.00
3×6
12.50
241.00
332.00
3×1.5
7.50
77.00
101.00
4×6
13.90
334.00
413.00
4×1.5
8.20
99.00
125.00
5×6
15.80
441.00
508.00
7×1.5
10.70
151.00
210.00
12×1.5
13.00
220.00
336.00
2×10
15.00
265.00
427.00
16×1.5
14.20
282.00
425.00
3×10
16.10
371.00
502.00
18×1.5
15.40
367.00
480.00
4×10
18.10
186.00
785.00
25×1.5
18.70
495.00
701.00
5×10
19.90
714.00
857.00
2×2.5
8.20
94.00
128.00
4×16
21.10
810.00
885.00
3×2.5
9.10
145.00
166.00
5×16
23.20
1040.00
1286.00
4×2.5
10.00
173.00
196.00
5×2.5
11.20
198.00
221.00
4×25
26.90
1162.00
1567.00
7×2.5
13.10
235.00
345.00
5×25
30.00
1438.00
1962.00
12×2.5
16.20
440.00
571.00
4×35
30.80
1587.00
2060.00
18×2.5
19.00
568.00
678.00
5×35
34.20
1928.00
2685.00
4×50
34.90
2150.00
3005.00
www.vopcables.com